Clean In Place (CIP) – is an automated and controlled cleaning method in an automated process for cleaning production equipment, piping, tanks and systems that are not accessible for manual cleaning without disassembly. The process is performed without manual intervention by circulating hot liquid cleaning agents such as acid/base mixtures, detergents, solvents and disinfectants. Water, cleaning agents and diluents are pumped through the piping system and tanks using pumps, while the CIP system regulates the flow of liquids, temperatures and concentrations of materials according to the defined cleaning program until a level of cleanliness appropriate to the type of biopharmaceutical product and its purpose is reached. The design of the CIP system also includes the sanitary design of the equipment and system. During the engineering design, it is important to consider all production facilities, production equipment, systems, infrastructure and the manner of storing dirty equipment and cleaned equipment at each stage.
Steam In Place (SIP) – is a process for disinfection by exposure to high heat or disinfectants such as hot steam, active oxygen or peracetic acid. The SIP process is designed to kill pathogenic bacteria and eliminate all types of microorganisms in critical equipment or systems that come into contact with sterile pharmaceutical products. The SIP process is carried out to sterilize the system before the start of the production process.
In the pharmaceutical and biotechnology industries, maintaining high levels of hygiene and sterility is mandatory.
When switching from batch to batch or campaign to campaign, it is necessary to ensure that there is no mixing between batches and that at the start of each batch all the necessary equipment is clean and sterilized.
Contamination or residues can arise from many reasons, including:
- Human factors
- Residues from the previous batch
- Aseptic work processes
- Exposure to the external environment
- Residues of disinfectants and more…
In order to remove the risk, it is necessary to perform effective, repeated and effective cleaning and sterilization processes for equipment, machinery and systems used in production.
Technological advances and the increase in regulatory requirements, along with the availability of sensitive and reliable sensors and measurement methods that can be installed as part of production systems, increase the need, demand and ability to switch to cleaning when the equipment is installed in place without dismantling the equipment. This cleaning method is called Cleaning in place (CIP).
This method replaces the manual process that includes: handling the equipment in the production room, dismantling, transferring it to the washing room, washing it manually or using a dishwasher, packaging, and then sterilizing it in an autoclave and returning it to the room to reassemble the system.
There is a clear trend of extreme caution on the manner of execution, frequency, and quality of cleaning processes by health authorities, especially the FDA. There is a dedicated technical report (TR45) that defines what is required to meet the requirements and how to perform validation with regard to the production and cleaning processes. The cleaning process constitutes the final stage of the production process that preceded it.
There are large pieces of equipment that there is no way to clean, let alone sterilize, except through Cleaning in Place (CIP) processes.
For each piece of equipment, it is necessary to understand what materials/factors need to be removed/cleaned: living agents such as viruses, fungi, yeast, bacteria. Is the material to be removed hydrophilic or hydrophobic, is it fatty, acidic, basic, etc.
As a first step, a cleaning cycle must be developed that can include a combination of: rinsing/heating/acid/base/mechanical force, etc.
After the cleaning cycle is determined, validation tests will need to be performed to ensure that the systems are operating properly and providing the required level of cleaning and sterilization. Periodic validation of the processes is necessary.
Periodic tests must be performed to identify possible failures and prevent malfunctions, including microbiological tests after cleaning and sterilization processes. Establishing CIP and SIP systems requires precise planning and consideration of production needs and the specific requirements of the industry. Regular maintenance and periodic inspections ensure that the systems continue to operate efficiently and meet the required standards. In summary, CIP and SIP systems offer an effective and efficient solution for cleaning and sterilizing machines in many industries, but they require an initial investment, ongoing maintenance, and periodic inspections to maintain their efficiency and reliability.
To ensure ongoing work in Cleaning in Place (CIP) processes, the availability and capacity of supporting systems must be ensured, including the supply of water, energy, and appropriate chemicals for cleaning and then for the sterilization process by sterilization.
Like any system, regular and scheduled maintenance is required to maintain the efficiency of the system, including cleaning and replacing worn components and testing the control systems.
CIP and SIP Systems: Process, Validation, and Consideration of Cleaning
Required Validation: Validation of cleaning processes requires consideration of both production facilities, production equipment, infrastructure systems, and the manner of storing dirty and cleaned equipment.
There is a clear trend toward compliance and validation with regard to production and cleaning processes.
Below is a table describing the principles and stages of cleaning in a CIP (Clean-In-Place) system, including the basic stages of the process, their role, and how they affect the efficiency and reliability of cleaning. Below is an example of such a table:
| Purpose | Description | Step |
|---|---|---|
| Avoid environmental contamination with living organisms | If there is living matter in the process, inactivation must be performed | Death |
| Reducing the dirt load | Usually initial flushing of the system with hot water to remove coarse residues | Spraying and spraying through water sprinklers |
| Removing most of the dirt and microorganisms | Flowing hot water with a base to dissolve proteins and fats | Base |
| Achieving a clean and residue-free surface | Using acid to remove residue | Acid |
| Ensuring final cleaning and preventing cross-contamination, at the end of this rinse, ensure that the TOC level is equal to that of the water in which the rinse is performed | Final rinse with hot or cold water to remove all traces of acid and base | Final rinse |
| Ensure that the residue level in the tank does not exceed the level defined for the water in which Rinsing is done | Must be performed with water at a level of cleanliness depending on the stage and type of product, for a sterile product for injection WFI is required | Final rinse |
| Integration of the SIP process to ensure sterility | Use of heat or chemicals for sterilization | Sterilization (as needed) |
The steps are built according to a necessary sequence that ensures that each part of the system receives the appropriate cleaning and sterilization treatment, as needed. Modern CIP systems can be customized and programmed to perform the process automatically, while monitoring and controlling parameters such as temperature, time, and chemical concentration, to ensure consistent and effective results.
In small-scale or laboratory production processes, which use laboratory process equipment, a mobile CIP system can be used, consisting of a cart containing tanks of detergent/cleaning agents and water of the required quality/steam at the required cleanliness level in addition to pumps and a basic control system, which are necessary for the proper running of the process and achieving good results. Mobile CIP systems can be easily moved from station to station, with simple manual connection to the system and operation according to needs. Large-scale manufacturing processes, which are often more complicated, will usually include an integral CIP system, which includes automated control and multiple cleaning steps.
Criteria to ensure that the cleaning process is correct is divided into a validation phase and ongoing testing
| Testing | Bolding testing | Ongoing testing | Limits | |
| Visual Inspection | Can be performed using a special dye or riboflavin | Looking as much as possible | No dye residue / clean | |
| bioburden (BB) | According to the permissible level in the water of the last rinse | At the frequency determined in risk management | ||
| TOC Total organic
carbon |
According to the permissible level in the water of the last rinse | It will usually be felt that only when it reaches the permissible threshold will the final rinse phase be stopped | ||
| Conductivity |
Equipment used in biopharmaceutical manufacturing processes should be designed according to the principles Sanitary design is designed to increase the likelihood that cleaning processes will be relatively easy to perform and will lead to a desired level of cleanliness. This includes selecting materials that are smooth and non-absorbent, and a geometry that does not leave areas where water will stagnate or areas where spraying is not optimal.
For example, some of the principles of sanitary design emphasize that difficult-to-clean areas should be as few as possible, using smooth surfaces such as glass or stainless steel with an appropriate degree of polish, without grooves or nozzles that trap contaminants, sealed, straight, and properly polished. Jet ball / Spray ball water sprayers or any other cleaning component are suitable in terms of type, number of units, and location, through which the cleaning agents will reach all areas that are difficult to clean and will allow sufficient coverage of the area being cleaned.
Ensure that drainage is carried out perfectly, with the correct location of the drain opening and the use of appropriate slopes to avoid stagnant water “dead legs”.
“Dead legs” are a situation where liquid is not completely drained and accumulates in the pipe, as well as a barrier that does not allow coverage of the cleaning/disinfectant in certain areas.
The design of the CIP system will include reference to the following parameters:
Physical and chemical properties: of the product/material to be cleaned as well as of the surface to be cleaned, toxicity, availability and environmental aspects, need for heating, etc.
Selection of the cleaning agent: suitability for the type of contaminant, the material from which the equipment being cleaned is made, the concentration and properties of the cleaning agent.
Selection of the spraying and/or mixing mechanism for the cleaning agents.
Volumes of cleaning solutions and water are handled at each stage and stage of the cleaning process.
Definition of the method for draining and neutralizing the disinfectant.
Construction and engineering principles of production equipment including materials and surfaces Flow rates of cleaning agents for spraying.
Cleaning cycle times will be affected by the complexity of the production system and the difficulty of removing material residues
As part of the cleaning cycle, a drying process must be defined by blowing, and it is necessary to define the time for maintaining the cleanliness of the equipment at the end of the cleaning process and during storage (Holding Time).
Specifications must be established for the quality of the cleaning agents used. The specifications must be tested and documented as required. It must be ensured that the quantities of cleaning agents and appropriate concentrations reach all parts of the equipment that require cleaning. All parameters that affect the CIP processes must be monitored and documented and must meet defined limits. A production system that has difficulty passing cleaning validation processes for a particular product will require the use of dedicated equipment for the production of the product.
The sampling methods accepted for cleaning validation depend on the type of product (physical and chemical properties) and the engineering characteristics of the equipment being sampled. Typically, the sampling method will combine visual inspection, rinse water, and swabs. The accepted analytical methods for testing the samples include methods such as:
A validation process should prove beyond a reasonable doubt that the CIP process does not support the growth of microorganisms during cleaning, after cleaning, and also during prolonged storage of the equipment. For products for which there is a specification regarding endotoxins, it is necessary to check the endotoxin levels as part of the validation of the CIP system.
Validation protocols required for a CIP system:
Installation Qualification – A protocol that aims to ensure that the CIP equipment and associated systems have been supplied and installed properly, in accordance with the specifications.
Operational Qualification – A protocol that aims to verify that the installed equipment and systems are operating as required.
Performance Qualification – A protocol that aims to verify that the installed CIP equipment and associated systems perform the cleaning operations within the desired parameters, while achieving the desired cleaning quality and meeting specifications, while using and simulating “Worst case” and “Worst to clean locations” situations.
Key advantages of CIP and SIP are consistent and uniform execution of cleaning and sanitizing operations, the ability to document and approve the processes, the absence of the need for manual access to closed systems, and lower time and resource consumption than in manual processes. However, the implementation of CIP and SIP requires a very high initial investment in dedicated systems, connections to production systems, special piping, storage tanks and automatic control.
Proper operation and maintenance of CIP and SIP systems are critical. This includes monitoring parameters such as flow, pressures, temperatures and concentrations of cleaning/disinfectant. Cleaning and disinfection programs must be validated and certified to be capable of achieving the required level of cleanliness and disinfection. In addition, detailed protocols must be followed for preventive maintenance of the systems, replacement of worn parts and treatment of water and cleaning/disinfectant.
In summary, CIP and SIP are key processes in the pharmaceutical industry for achieving high levels of cleanliness and disinfection of equipment and personnel and are necessary to meet stringent regulatory and standardization requirements. Proper operation of these systems is critical to ensuring the quality, safety and reliability of pharmaceutical products.
Relevant regulations and standards that address CIP and SIP processes in the pharmaceutical industry:
FDA cGMP – The FDA’s Current Good Manufacturing Practices (CMP) include specific requirements for cleaning and sanitizing manufacturing equipment:
21 CFR 211.67 – Requires companies to establish and maintain good manufacturing practices for cleaning and preventive maintenance of equipment.
21 CFR 211.192 – Requires equipment to be cleaned and sanitized in accordance with recognized validation programs.
EudraLex Volume 4 Annex 1 – The supplement to the EU’s Good Manufacturing Practices addresses requirements for cleanrooms and sterile manufacturing, including specific requirements for CIP/SIP processes.
ISPE Baseline Guide: Sterile Product Manufacturing Facilities – This ISPE (Social Security Industry Association) guide includes detailed recommendations for the design, implementation, and documentation of CIP/SIP processes.
ASTM E3106 – American Society for Testing and Materials standard that deals with CIP cleaning of closed containers.
Planning and work steps to achieve effective CIP/SIP cycles:
- Conduct a comprehensive risk assessment to identify the specific cleaning and disinfection needs of each equipment/system.
- Build detailed plans that include sequence of operations, types of cleaning/disinfectant, concentrations, temperatures, pressures, exposure times, etc.
- Determine critical parameters for monitoring and controlling the processes.
For example for CIP – :
- Detergent temperature – A defined temperature range should be maintained for each cleaning agent to ensure maximum effectiveness.
- Detergent concentration – Concentrations that are too low or too high may negatively affect cleaning effectiveness.
- Detergent exposure time – The exposure time required for each cleaning agent to remove Dirt/residue.
- Pressure/Flow – A minimum pressure range and flow rate should be maintained to ensure adequate penetration of the cleaning agents.
- Cleaning agent flow order – The correct order for the flow of acids, bases, detergents and rinse agents should be followed.
- Cleanliness of the final rinse water – Check that there are no cleaning agent residues in the water after the cycle is complete.
For example for SIP:
- Steam/disinfectant temperature – Exceeding the defined temperature range will impair the disinfection efficiency.
- Steam pressure – A minimum steam pressure should be maintained as defined to achieve the required disinfection temperature.
- Steam/disinfectant exposure time – The minimum exposure time required to destroy microorganisms.
- Quality Steam – Ensure that the steam is free of particles and chemical/biological contaminants.
- Steam/disinfectant spread – Monitor to ensure full penetration of all equipment and system components.
- System sealing – Essential to ensure hermetic closure during disinfection to prevent leaks.
- Monitoring disinfection cycles – Documenting each SIP cycle, critical parameters and test results.
- Critical monitoring and control of all these parameters in real time and their documentation are critical to ensuring the efficiency of the CIP and SIP processes and compliance with regulatory and standardization requirements.
- Ensure thorough intermediate rinsing and complete disposal of cleaning agents after each step.
- Verify that the processes are capable of achieving the required level of cleanliness/disinfection through analytical and biological testing.
- Document the processes and monitoring results Throughout the CIP/SIP cycle.
- Establish preventive maintenance procedures for periodic inspections, treatments, and replacement of critical components.
- Guide and train teams to fully understand CIP/SIP processes and their importance.
It is important to note that CIP/SIP programs must be specific to equipment, processes, and products and must undergo prior regulatory validation and approval.